How to Design Schematic Circuit of Photometer.

 Some of the most common applications for LDRs are as sensing elements in alarms, photo-relays, counters, light meters for photography and also experiments in optics.

The project described here is a simple light meter made from an LDR (Light Dependent Resistor or Photoresistor), a 0-200uA microammeter, and a 3V battery formed by two AA cells.

Use any general-purpose LDR with a high dark-to-light resistance ratio. Since the circuit is operating for short durations you don't need an ON-OFF switch. Just put the cells in the battery holder when using the unit.

Pl adjusts sensitivity to the range of your working light intensity. Circuit shows the schematic of the Photometer. The ammeter is not critical. Any type with full scale ranging from 100uA to 1 mA can be used. circuit 2 shows a mounting view, using a terminal strip as chassis. 

The device can be housed in a small plastic box. The meter and LDR are placed on the front panel.

if the ammeter used is out of specification, you need to adjust P1. Try values between 10,000 and 100,000 ohms. The LDR can be housed in a small opaque tube, depending on the application.



Parts List - Photometer

LDR - Any common LDR (Light Dependent Resistor)

M1 - 0-200uA - meter - see text

P1 - 100,000 ohm trimmer potentiometer

R1 - 10,000 ohm, 114W,5% resistor

81 - 3V - two AA cells